Lesson learned after the Emilia-Romagna, Italy, 20–29 May 2012 earthquakes: A limit analysis insight on three masonry churches

Descrizione

Abstract:

"Three masonry churches collapsed or severely injured during the 20–29 May 2012 earthquakes occurred in Emilia-Romagna, Italy are analyzed in detail from a numerical standpoint. A recently presented standalone 3D limit analysis code is utilized to evaluate failure mechanisms and horizontal acceleration causing the collapse. A comparison with the recent Italian Guidelines devoted to the safety assessment of monumental buildings is also provided. The horizontal acceleration associated to the first active failure mechanism is compared with that actually active during the 20–29 May shakes. A preliminary modal analysis is also conducted to evaluate vibration modes, to compare the numerical limit analysis acceleration with the spectral acceleration kept by the structures."

Dettagli
INFO BIBILIOGRAFICHE
In "Engineering Failure Analysis", XXXIV, dic. 2013, pp. 761-778.
Anno
2013
pubblicazione
collegamento esterno
Allegati
Nessun allegato presente
SISMA EMILIA 2012
DOCUMENTAZIONE SISMA EMILIA 2012
Portale di riferimento atto a svolgere funzione informativa e documentale.
ALTRI CONTATTI
Centro documentazione sisma 2012
Via Luosi 40 Mirandola, MO
Regione Emilia Romagna
Viale Aldo Moro ,52 40127 Bologna

Tutti i diritti riservati - 2019 - Sisma Emilia 2012 - Privacy Policy - Cookie Policy